Interconnecting links/ Shorting links:-

Interconnecting links or shorting links are used to interconnect two or more terminal blocks of same type and at the same potential. it is recommended that factory made shorting links which are designed considering the rated current of the terminal block and its pitch are used for interconnection purpose rather than looping by wire which is not a reliable practice.

elmex offers following types of shorting links:-

Permanent Cross Connection Link Assembly (CCLA):-
This type of link assemblies are used to permanently short terminal blocks. The link comprises of a shorting link/ bar, screws, spring washer and sleeves. This link assembly is supplied in ready to use form for quick cross connection. these links are available in 2,3,4,5 and 10 ways.

Removable Shorting Link (RSL):-
Removable shorting links are used to interconnect two adjacent terminal blocks temporarily and make switchable cross connection. The links are fitted onto the terminal blocks with long studs and screws. As the links rest above the top surface of the terminal blocks, they can be readily opened up.
For a pair of terminal blocks to be shorted, one removable link and two studs are required. Further, since the links rest above the top surface of the terminal block, it is recommended to mount a barrier plate/ partition plate between two adjacent pairs of shorted terminal blocks.

Comb Type Shorting Links (UFSL & SLC):-
In two types of shorting links as described above, interconnection is made using screws/ studs through a tapped hole in current bar. For certain types of terminal designs, viz. stud type terminal blocks, such interconnection is not possible. As a solution to this problem, shorting links are designed to interconnect adjacent terminal blocks through termination points (where wire is connected) like stud and nut assemblies or clamping units from sides between adjacent terminal blocks. These links are generally available in 2,3,4,5 and 10 ways.

Push-in Type Shorting Links (DSL/MSL/SSL):-
These types of links are designed for screwless type terminal blocksand are avilable in two ways. A stack of terminal blocks of the same type can be shorted using two way shorting links. These shorting links are push-in type.
Current bars in these terminals have provision to accept two shorting links which can be inserted from top. Thus we can short two terminal blocks with one shorting link, three terminals with two shorting links, four terminals with three shorting links and so on.


Accessories.gif



Cross Connection Link Assembly
Type Suitable for Terminal Type
CCLA1.5 - 2W SUT 1.5
CCLA10 - 2W CST 10, CUT 10, KUT 10, KUT 10N
CCLA16 - 2W CST 16, KUT 16
CCLA1L - 2W CSLT 1
CCLA1LK - 2W KULT 1
CCLA2.5 - 2W CST 2.5, CST 2.5WS, CUT 4, KST 4UWS, KUT 4
CCLA25 - 2W CST 25, KUT 25
CCLA35 - 2W CST 35
CCLA35K - 2W KUT 35
CCLA4N-2W KUT 4N, KUT4 - 1x2, KUT4 - 2x2
CCLA50 - 2W KUT 50
CCLA6 - 2W CST 6, CST 6WS, CUT 6, KST 6WS, KUT 6
CCLA95 - 2W KUT 95
CCLADD - 2W CUDD 4, KU2D 4, KUDD 4, PET 4, SUT 4
CCLAK4 - 2W KULT 4
CCLAK6 - 2W KULT 6
CCLATD - 2W DU3D 4, DUSD 4
CCLK2.5 - 2W KUDD 4N, KUT 2.5N, KUTM 2.5
CCLM2.5 - 2W CSTM 2.5, CUTM 2.5
CCLM2.5K - 2W KUT 2.5
SLE - 2W CET 4, NET 4
SLU10 - 2W UBT 10
SLU4 - 2W MBT 4, UBDD 4, UBT 2.5, UBT 4, UBT 4 TWIN
SLU6 - 2W UBT 6
Comb-type Shorting Link
Type Suitable for Terminal Type
ADSL - 10W CABT M4
ADSL - 2W CABT M4, CAT M4, CAT M5, CATD M4, CLTD M4
ADSL - 3W CABT M4
ADSL - 4W CABT M4
ADSL - 5W CABT M4
ADSLR-2W CAT M4, CAT M5, CLTD M4
ASL1 - 2W CAT M3
BSL6-2W CBT M6
CLUF - 2W UBDF 4, UBDF 4A, UBDF 4D
KDSL4 - 2W KLTD M4
KSL 4 - 10W KABT M4
KSL 4 - 5W KABT M4
KSL3 - 2W KAT M3
KSL4 - 2W KABT M4, KAT M4, KAT M5, KBT M4
KSL4 - 3W KABT M4
KSL4 - 4W KABT M4
KSL5 - 2W CBT M4, CBT M5, KBT M5-15
KSL6 - 2W KBT M6
OSL2.5 - 2W OAT 2.5
OSL6 - 10W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6 - 2W OAT 6, OAT 6DTS, OAT 6DTS - 2 WAY, OAT 6T
OSL6 - 3W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6 - 4W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6 - 5W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6R - 10W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6R - 2W OAT 6, OAT 6DTS, OAT 6DTS - 2 WAY, OAT 6T
OSL6R - 3W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6R - 4W OAT 6DTS, OAT 6DTS - 2 WAY
OSL6R - 5W OAT 6DTS, OAT 6DTS - 2 WAY
SLC 6SL - 2W KPCH 6, KUDT 6
SLC 6SL - 4W KPCH 6, KUDT 6
SLC10N - 2W CST 10, CUT 10, KUT 10
SLC2.5 - 2W CST 2.5, CST 2.5WS, KST 4UWS, KUT 4
SLC2.5N - 2W KUTM 2.5
SLC4N - 2W CSTM 2.5, CUDD 4, CUDD 4S, CUTM 2.5, DU3D 4, DUSD 4, KPCH4, KU2D 4, KU2D 4S, KUDD 4, KUDT4-2x2, KULT 4, KULTD 4, KULTD 4WS, KUT 2.5, KUT4 - 1x2, KUT4 - 2x2, PET 4, SUT 4, testing-final-offline
SLC4N-2W KUT 4N
SLC6 - 2W CST 6, CST 6WS, CSTD 6, CUT 6, KST 6WS, KULT 6, KUT 6, KUTD 10, KUTSD 6
SLD6 - 2W KULTD 6, KUPDS 6, KUPTD 6, KUPTD 6-S, KUPTD 6S
UFSL - 2W KUDDF 4, KUDDF 4A, KUDDF 4D, KUDF 4, KUDF 4A, KUDF 4D
Link for Removable Shorting
Type Suitable for Terminal Type
RSL10 CST 10, CUT 10, KUT 10
RSL16 CST 16, KUT 16
RSL1L CSLT 1, KULT 1
RSL2.5 CST 2.5, CST 2.5WS, CUT 4, KST 4UWS, KUT 4
RSL25 CST 25, KUT 25
RSL35 CST 35
RSL35K KUT 35
RSL6 CST 6, CST 6WS, CUT 6, KST 6WS, KUT 6
RSLDD CUDD 4, KUT 4N, KUT4 - 1x2, KUT4 - 2x2
Long Stud For Removable Shorting
Type Suitable for Terminal Type
LSR10-16 CST 10, CST 16, CUT 10, KUT 10, KUT 16, KUT 25
LSR1L CSLT 1, KULT 1
LSR2.5-6 CST 2.5, CST 2.5WS, CST 6, CST 6WS, CUT 4, CUT 6, KST 4UWS, KST 6WS, KUT 4, KUT 6
LSR25 CST 25
LSR35 CST 35
LSR35K KUT 35
LSR6N CUDD 4, KUT 4N
Copyright 2011 Elmex.alogue Designer